PRO1 · Standalone

PRO1 T751 Non-Programmable Universal Thermostat

The T751 is a non-programmable thermostat for conventional multistage systems or heat pumps.

PRO1 T751

PRO1 T751

Will this work with my system?

Match your equipment to these requirements before ordering.

Works with

  • Staging: Up to 2 heat / 2 cool conventional; 3 heat / 2 cool heat pump

System requirements

  • Power: 2 AA alkaline batteries or 18–30 VAC, NEC Class II, 50/60 Hz
  • Electrical load limits: 1 A per terminal; 1.5 A maximum combined

Check before you buy

  1. Match the full T751 model number and hardware revision to the manufacturer's equipment manual and accessory list.
  2. Compare the equipment terminals, control voltage and required operating sequence with the model-specific installation diagrams.
Manufacturer documentation (2)

Use these documents to compare your exact model and configuration.

Overview

The T751 is a non-programmable thermostat for conventional multistage systems or heat pumps. It supports up to two heating and two cooling stages for conventional equipment, or three heating and two cooling stages for heat pumps.

Its 7-square-inch blue-backlit display and adjustable setpoint limits support local control. Automatic changeover is available outside PTAC mode, subject to installer configuration.

The thermostat can use two AA alkaline batteries or a suitable hardwired supply. Use the exact-model installation manual to match the thermostat configuration, equipment and wiring before installation.

Product details

Manufacturer
Pro1 iAQ
SKU
105419
Model / MPN
T751
Condition
New
Lifecycle
Current

Specifications

Stage modes
Up to 2 heat / 2 cool conventional; 3 heat / 2 cool heat pump
Scheduling modes
Non-programmable
Power sources
2 AA alkaline batteries or 18–30 VAC, NEC Class II, 50/60 Hz
Setpoint range
44 to 90 °F (7 to 32 °C)
Operating temperature
32 to 105 °F (0 to 41 °C)
Operating humidity
90% RH maximum, non-condensing
Backlit display
Blue backlight
Contact ratings
1 A per terminal; 1.5 A maximum combined
Setpoint limits
Adjustable heating maximum and cooling minimum; see installer settings
Measurement channels
Temperature display range: 41 to 95 °F (5 to 35 °C)