White-Rodgers · Standalone
White-Rodgers 1F95EZ-0671 Blue Easy Reader Thermostat
Easy Reader thermostat with selectable 7-day or non-programmable operation for conventional, multistage and heat-pump systems.
Legacy model
Will this work with my system?
Match your equipment to these requirements before ordering.
Works with
- Conventional gas, oil or electric systems up to 2H/2C
- One- or two-compressor-stage heat pumps with up to two auxiliary/emergency heat stages
- Documented two- or three-wire hydronic zone and millivolt applications
System requirements
- NEC Class II control wiring; do not connect line-voltage heating circuits.
- Select SS1, MS2, HP1 or HP2 to match the equipment; configure gas/electric fan operation and dual-fuel logic when applicable.
Check before you buy
- Compare the installed equipment voltage, stage count and terminal functions with the installation manual before selecting this model.
- Count compressor stages separately from auxiliary stages; the 4H/2C maximum includes auxiliary heat.
- For two-transformer conventional systems, compare the equipment with the separate-transformer wiring diagram.
Manufacturer documentation (1)
Use these documents to compare your exact model and configuration.
Overview
Easy Reader thermostat with selectable 7-day or non-programmable operation for conventional, multistage and heat-pump systems.
Choose non-programmable operation or a separate schedule for each day, with two or four periods. Installer settings provide heating and cooling setpoint limits. The manual covers conventional single- and multistage systems, heat pumps, and three-wire zone valves; each uses a different wiring configuration.
Selection and installation
Use the linked manufacturer documents to compare the exact model, equipment configuration and installation requirements before ordering.
Product details
- Manufacturer
- Copeland Comfort Control
- SKU
- 907756
- Model / MPN
- 1F95EZ-0671
- Condition
- New
- Lifecycle
- Legacy
Specifications
- Power sources
- Two AA alkaline batteries, with power-stealing assist; optional 20–30 VAC hardwired power
- Stage modes
- Conventional: up to 2H/2C; single-compressor heat pump: up to 3H/1C; two-stage heat pump: up to 4H/2C, including up to two auxiliary/emergency heat stages
- Scheduling modes
- 7-day or non-programmable
- Schedule periods per day
- 2 or 4 in programmable mode
- Setpoint range
- 45–99 °F
- Setpoint limits
- Heating maximum adjustable 62–98 °F (99 °F default); cooling minimum adjustable 46–82 °F (45 °F default)
- Contact ratings
- 1.5 A per terminal; 2.5 A combined maximum
- Operating temperature
- 32–105 °F
- Operating humidity
- 90% RH maximum, non-condensing
- Dual transformer support
- Conventional systems supported with RH/RC jumper removed, per diagram
- Millivolt support
- Documented for conventional systems
- Dual fuel support
- Selectable logic-based heat-pump/gas or oil auxiliary operation
- System modes
- Heat; A/C; Off; auxiliary heat in heat-pump configuration
- Dimensions
- 4-3/16 in H × 6-1/2 in W × 1-5/8 in D